ART Pro Audio DMV-Pro - Dual True-Stereo Effects Processor User Manual
Page 56

- 52 -
Byte Number
Value (in hex)
Description
1
F0
Start of SysEx message.
2
1A
A R T manufacturer’s ID.
3
0x
MIDI channel (00 to 0F).
4
22
DMV-PRO product ID.
5
??
Function ID.
...
??
(data, zero or more bytes)
(last)
F7
End of SysEx message.
The Function ID is one of the following values and is followed by zero or more bytes of data, as implied by the
function.
Function ID
Function Class
Direction
Description
41
Unit Handshake
to Unit
Ask DMV-PRO to respond. This may be used to test if a
DMV-PRO is present and listening on the MIDI network.
01
from Unit
Handshake response from DMV-PRO.
4B
Parameter
Exchange
to Unit
Ask DMV-PRO to dump presets.
0b
to Unit
Upload a past preset dump from the DMV-PRO.
0b
from Unit
“Dump Presets” response from DMV-PRO.
4D
Unit Status
to Unit
Ask DMV-PRO to report system status.
0D
from Unit
System status response from DMV-PRO.
The SysEx message to make the DMV-PRO dump all presets is:
F0 1A 0x 21 4B F7
Other MIDI Notes
The DMV-PRO ignores inbound Active Sensing messages.
The DMV-PRO does not generate Active Sensing messages.
The System Reset message is ignored.