Hardware Preparation and Installation
ARTM-9405 16x10GbE Installation and Use (6806800P45F)
21
2.5.1.2
Front Blade is not Installed
Use this procedure to install the RTM when the front blade is not installed.
1. Locate the slot where the RTM is to be installed into the shelfs rear, which must be the same
as that of the front blade.
2. Make sure that the top and bottom handles of the RTM are in an outward position by
squeezing the lever and latch together.
3. Insert the RTM into the shelf by placing the top and bottom edges in the card guides of the
slot.
4. Slide the RTM into the slot.
5. Apply equal and steady pressure to the RTM to carefully slide it into the shelf until you feel
resistance.
6. Continue to gently push the RTM until the RTM connectors engage.
7. Squeeze the lever and latch together, and then hook the lower and upper handle into the
shelf rail recesses.
8. Fully insert the RTM and lock it to the shelf by pressing the two components of the lower
and upper handles together, and then turn the handles toward the face plate.