U-Boot provides "date" commands to operate the RTC features. These include get/set/reset
date and time.
The following are usage samples for "date" on the COMX-P4080.
date
Date: 2010-12-01 (Wednesday) Time: 17:57:37
date reset
Reset RTC
Date: 2010-18-01 (Sunday) Time: 0:00:00
date 120117592010.00
Date: 2010-12-01 (Wednesday) Time: 17:59:00
U-Boot provides "wdt" commands to operate on the WDT features.
The following are usage examples of "wdt" for the COMX-P4080.
wdt status
WDT: disabled.
wdt enable 5
WDT: enabled with timeout 5 seconds.
date [MMDDhhmm[[CC]YY][.ss]]
date reset
without arguments:
Prints date and time
with numeric argument:
Sets the system date and time
with ’reset’ argument:
Resets the RTC
wdt reset
-
Resets WDT
wdt status
-
Checks the current status of WDT
wdt disable
-
Disables WDT
wdt enable <timeout#>
-
Enables WDT with timeout <timeout#> seconds.
<timeout#> range [1...124]