BSF(diag-SP_VEE0-networkinterface)#list-device-instances

nwcontlr(131), eth0(62),eth1(63),eth2(64)

BSF(diag-SP_VEE0-networkinterface)#show-test-result testId 1

deviceInstance 63

Test Result: PASSED

Test Started Invocation Id: 7

Test Start Time: Mon Nov 26 09:31:22 2012

Test Stop Time: Mon Nov 26 09:31:23 2012

Test Log File:

/opt/diagnostics/var/log/diag/testlog/NETWORK_eth1.log

Using CLI, you can list all the Inservice diagnostics monitors in a device category. By default, all
the monitors are started when ViewCheck application is initialized. User can use start-monitor
and stop-monitor commands to start and stop any monitor.

BSF(diag-SP_VEE0-networkinterface)#show-monitor-id

Mon Nov 26 09:36:06 2012

DeviceCategory: NETWORK

Monitor Name: NETWORK ERRORS VALUES

MonitorId: 1020

DeviceInstance:

eth0 eth1

Monitor Name: NETWORK COUNTERS VALUES

MonitorId: 1021

DeviceInstance:

eth0 eth1

BSF(diag-SP_VEE0-networkinterface)#start-monitor monitorId 1020 deviceInstance 63
MONITOR IS ALREADY STARTED

BSF(diag-SP_VEE0-networkinterface)#stop-monitor monitorId 1020

deviceInstance 63

MONITOR IS STOPPED