U-boot deployment – Artesyn COMX-P2020 BSP User Guide (July 2014) User Manual
Page 52
U-boot Deployment
COMX-P2020 BSP User Guide (6806800L84B)
52
Chip probe:
i2c dev 0
Setting bus to 0
i2c probe
Valid chip addresses: 50 70
Excluded chip addresses: 29
=>
The following command can be used to program the ID EEPROM:
Set Tag value:
mac id
Program system serial number, for example: 12345678901
mac n 12345678901
Program errata data, for example: 1234
mac e 1234
Set program date, for example: 2010-4-30 16:50:50
mac d 100430165000
Program the number of ports:
mac p 3
Program the MAC address for port X [X=0...2], for example:
mac 0 00:05:9f:ff:91:01
mac 1 00:05:9f:ff:91:02
mac 2 00:05:9f:ff:91:03
0x4E - 0x53
MAC Address 3
6 Byte
00h 21h 79h b5h
1eh dah
Means:
00:21:79:b5:1e:da
MAC Address for
eTSEC3
Variable
0x54 - 0x71
Reserved
30 Byte
Reserved
Static
0x72 - 0x75
CRC32
4 Byte
00h a0h 14h 10h
Means the CRC is:
0x00A01410
32 bit CRC of values
0x00 through 0x71,
inclusive
Variable
0x76 - 0xFF
Reserved
138 Byte
Reserved
Static
Table 5-3 Content for ID EEPROM (continued)
Address
Name
Length
Value/Example
Description
Static/Variable