Technical Data

CV-C Controller

Power

24 Volt AC

Weight

1.5 lb.

Power Consumption

12 VA Maximum

Network Connection

RS-485

Operating Temp

10

°

F to 149

°

F

Protocol

HSI Open Protocol Token Passing

Operating Humidity

90% RH Non-Condensing

Communications

RS-485 - 9600 Baud

Inputs:

Outputs:

Quantity Available

Types

Quantity Available

Types

Type III-10kohm Sensor

Binary

0-10 VDC Sensor

0-5 VDC Sensor

5

Onboard Relays (2 Amp @ 24 VAC)

N.O. Contacts with Suppressors

4-20mA Sensor

Analog

6

Binary Contact Closure

1

Modular Phone Jack For

Optional Airflow or SP Sensor

2

0-10 Volt DC Out

WattMaster reserves the right to change specifications without notice

One Year Warranty

Relay Outputs

Only Relay Output #1 (Fan On/Off Only) has a specific function
that cannot be changed. All other outputs are user configurable
in one of the following modes:

0 - Not Used (Nothing connected to this output )

1 - Heating Stage

2 - Cooling Stage

3 - Humidifier Enable

4 - De-Humidifier Enable

5 - Scheduled Relay from Internal Schedule

6 - Scheduled Relay from External Schedule (Only 1
Available!)

There are a total of 12 relays that can be configured. Four are
found on the Controller itself (R2 - R5) and the remaining eight
(R6 - R13) are found on the Optional Relay Expansion Board that
can be connected to the PJ2 expansion input.

Mounting

The CV-C Controller is provided with an integral backplate for
mounting inside of a control enclosure. An optional factory control
enclosure for the CV-C Controller is available.

Analog Outputs

There are two Analog Outputs available on this
controller. They are both user configurable as follows:

0 - Not Used (Nothing connected to this
output)

1 - Economizer (Requires either Supply Air or
Mixed Air Sensor)

2 - Relief Fan VFD Signal (Requires Relief
Pressure Sensor)

3 - Chilled Water Valve (Requires Supply
Sensor)

4 - Hot Water Valve (Requires Supply Sensor)

5 - Humidification/De-Humidification
(Requires Humidity Sensor)

Description

The CV-C Controller is a configurable controller that
allows for user configurable inputs and outputs. CV-C
Controllers also have provisions for mounting a Relay
Expansion Board to provide additional heating or cooling
staging capability.

Analog Inputs

Only Analog Input #1 (Space Temp Sensor Only) and
Analog Input #6 (Airflow Sensor Only) have a specific
function that cannot be changed. All other inputs are user
configurable in one of the following modes:

0 - Not Used ( Nothing connected to this input )

1 - Slide Offset (Requires Flush Mount Wall
Sensor with this Option)

2 - Supply Air Temperature

3 - Return Air Temperature

4 - Mixed Air Temperature

5 - Outdoor Air Temperature (Will broadcast to
ALL other controllers)

6 - Humidity Sensor (4-20 ma scaling)

7 - Humidity Sensor (0-5 VDC scaling)

8 - CO² Sensor (4-20 ma scaling)

9 - CO² Sensor (0-5 VDC scaling)

10 - Relief Pressure Sensor (Requires 0-5 VDC
±0.3" WG Sensor)

11 - Dirty Filter Contact (Normally Open)

12 - Alarm Contact (Normally Open)

13 - Alarm Contact (Normally Closed)

14 - Fan Status Contact (Normally Open)