Continued

REMEDY

1. Fully open manual

shut-off valve.

2. Press in control knob

fully.

3. After pilot lights, keep

control knob pressed in
30 seconds.

4. Wait one minute for

safety interlock system
to reset. Repeat ignition.

5. Hand tighten until

snug, then tighten 1/4
turn more.

6. A) Contact qualified

service person to
properly adjust pilot
flame.
B) Contact local
propane gas company.
C) Clean pilot (see
Cleaning and Mainte-
nance
, page 26) or
replace pilot assembly.

7. Replace thermocouple.

8. Replace control valve.

1. Fully depress control

knob in any position
other than pilot. Wait one
minute for safety inter-
lock system to reset. Re-
peat ignition.

2. Clean burner (see

Cleaning and Mainte-
nance
, page 26) or
replace burner orifice
(see Changing Burner
Orifice,
page 34).

3. Replace burner orifice

(see Changing Burner
Orifice,
page 34).

4. Contact local propane

gas company.

OBSERVED
PROBLEM

Pilot lights but flame
goes out when
control knob is
released.

Burner does not light
after pilot is lit.

POSSIBLE
CAUSE

1. Manual shutoff valve

not fully open.

2. Control knob not fully

pressed in.

3. Control knob not

pressed in long enough.

4. Safety interlock system

has been triggered.

5. Thermocouple connec-

tion loose at control
valve.

6. Pilot flame not touching

thermocouple, which
allows thermocouple to
cool, causing pilot
flame to go out. This
problem could be
caused by any or all of
the following:
A) Improperly ad-

justed pilot flame

B) Low gas pressure
C) Dirty or partially

clogged pilot

7. Thermocouple dam-

aged.

8. Control valve damaged.

1. Safety interlock

system has been
inadvertently trig-
gered.

2. Burner orifice is

clogged.

3. Burner orifice diameter

is too small.

4. Inlet gas pressure is

too low.

Advertising