Technical service, Service hints, Specifications – Desa GVR50PA User Manual

Page 35

Advertising
background image

35

100791

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

35,000 BTU/Hr 50,000 BTU/Hr

65,000 BTU/Hr

Model

Model

Model

BTU

35,000

50,000

65,000

Type Gas

Propane Only

Propane Only

Propane Only

Ignition

Piezo

Piezo

Piezo

Pressure Regulator Setting 10.5" W.C.

10.5" W.C.

10.5" W.C.

Inlet Gas Pressure

Maximum

14" W.C.

14" W.C.

14" W.C.

Minimum

11" W.C.

11" W.C.

11" W.C.

Dimensions, Inches

Heater (H x W x D)

25 x 27

1

/

4

x 16

27 x 32

1

/

2

x 16

31 x 37

3

/

4

x 16

Shipping Weight (pounds) 97

133**/120

158**/145

Flue Vent Size

4" dia.

4" dia.

5" dia.

Orifice Size

52 drill, ø .0635

46 drill, ø .081

2.4 mm, ø .0945

** When equipped with blower

SPECIFICATIONS

When gas pressure is too low

• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low

When gas quality is bad

• pilot will not stay lit
• burner will produce yellow flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.

SERVICE

HINTS

Note:

These heaters are certified for elevations of 0-4500 feet above sea level. For

elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.