Trouble- shooting, Warning – Desa GVR50PA User Manual

Page 31

Advertising
background image

31

100791

If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

TROUBLE-

SHOOTING

POSSIBLE
CAUSE

1. Heater burning vapors

from paint, hair spray,
glues, etc.

2. Low fuel supply
3. Gas leak.

See Warn-

ing statement at
top of page.

1. Heater not venting

correctly. Vent safety
switch shuts off
heater.

2. Low line pressure.

3. Pilot partially clogged.

1. Gas leak.

See Warn-

ing statement at
top of page.

2. Control valve damaged.

1. Foreign matter be-

tween control valve
and burner.

2. Gas leak.

See Warn-

ing statement at
top of page.

3. Foreign fumes in area

of heater being drawn
through burner com-
bustion.

OBSERVED
PROBLEM

Heater produces
unwanted odors.

Heater shuts off in
use.

Gas odor even when
control knob is in
OFF position.

Gas odor during
combustion.

REMEDY

1. Ventilate room. Stop

using odor causing
products while heater is
running.

2. Refill supply tank.
3. Find and correct all

leaks (see Checking Gas
Connections
, page 13).

1. Check venting system.

If damaged or blocked,
repair. If venting system
is OK, have qualified
service person replace
vent safety switch, wire
harness, or thermo-
couple interrupter.

2. Contact local propane

gas company.

3. Clean pilot (see Clean-

ing and Maintenance,
page 26).

1. Find and correct all

leaks (see Checking Gas
Connections
, page 13).

2. Replace control valve.

1. Take apart gas tubing

and remove foreign
matter.

2. Find and correct all

leaks (see Checking Gas
Connections
, page 13).

3. Ventilate area around

heater to remove any
foreign fumes.