Tove, Nstallation, Cont – Avalon Firestyles Chelan DV-1996 to 1999 User Manual
Page 12

P
AGE
12
S
TOVE
I
NSTALLATION
(
CONT
.)
- For Qualified Installers Only!
Approved Configurations with a Vertical Termination and Two 90
°
Elbows
¥ The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
5 feet
10 feet
15 feet
20 feet
25 feet
30 feet
0 feet
35' (max)
5 feet
10 feet
15 feet
0 feet
5 feet
10 feet
15 feet
16'(max)
5 feet
15 feet
20 feet
25 feet
30 feet
0 feet
0 feet
NOTE:
Horizontal sections require a
1/4" rise every 12" of travel.
10 feet
Restrictor
Position # 7
Restrictor
Position #6
35' (max)
16'(max)
NOTE:
Restrictor positions are
based upon lab tests.
The ideal restrictor
position may vary
slightly, especially when
the termination is near a
demarkation line.
11 feet (min.)
Restrictor
Position # 5
Restrictor
Position # 4
NOTE:
The vent
must
terminate
within one
of the
shaded
regions.