Facing detail, Nstallation, For qualified installers only – Avalon Firestyles DVS Fireplace-1997 to 2000 User Manual
Page 11

I
NSTALLATION
(C
ONT
.)
- For Qualified Installers Only!
P
AGE
11
Facing Detail
Access Door
1-1/2"
Face
1"
1-7/16Ó Lopi Discovery
1-7/16Ó Avanti DVS
7/16Ó FPX Rect. and Arched
Glass
1/8"
Air Space
The overlap is 1-1/2" along
the top of the face.
NOTE:
Do not tuck tile underneath the face on the bottom (there
will be a 1/8" air space below the access door). You may
do this on the sides and top, but not on the bottom.
29-1/8Ó
20-3/8Ó
1"
1-1/2"
Make sure these shaded areas are faced over
when using the arched face. Rectangular faces
do not require this area to be faced.
2Ó
4-7/8Ó
+
To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing
directly next to the fireplace. See the illustration below.
Fireplace
1"
1/2" Drywall
1/2" Concrete Board
3/8" Tile
This 2x4 is recessed 3/8"
to make a flush facing
Fireplace
1/2" Drywall
1/2" Concrete Board
3/8" Tile
The tile overlaps the drywall
for an overlap facing
Faceplate
1"
TOP
VIEW
Faceplate