Vertical terminations, Nstallation – Avalon Firestyles DVS Fireplace-1997 to 2000 User Manual
Page 18

P
AGE
18
I
NSTALLATION
(C
ONT
.)
- For Qualified Installers Only!
Approved Venting Configurations for
Vertical Terminations with or without
Offsets
¥
11 Foot Minimum System Height (with or
without offsets)
¥
35 Foot Maximum System Height
¥
8' 7" Maximum Offset
¥
A Maximum of Two 45¡ Elbows May be
Used
¥
The termination must fall within the shaded
area shown in the chart. Use the indicated
restrictor position.
Offset
Length
Horizontal
Offset
Vertical
Rise
Offset Length
Hor. Offset
Vert. Rise
None
5"
1'
1' Section
1'
1' 7"
2' Section
1' 9"
2' 4"
3' Section
2' 5"
3'
4' Section
3' 2"
3' 8"
4' + 1' Section
3' 9"
4' 4"
4' + 2' Section
4' 6"
5'
4' + 3' Section
5' 2"
5' 9"
4' + 4' Section
6'
6' 9"
5 feet
11' (min.)
15 feet
20 feet
25 feet
30 feet
0 feet
35' (max.)
0 feet
3 feet
6 feet
5 feet
0 feet
0 feet
The maximum offset
length is three 4'
sections.
Restrictor
Position # 3
3 feet
6 feet
11' (min.)
15 feet
20 feet
25 feet
30 feet
35' (max.)
8' 7"
(max.)
8' 7"
(max.)