Maximum Shock

Storage

Half sine shock on all six sides of 71G 5% with a
pulse duration of 2ms 10% Square wave shock on
all six sides of 27G with velocity change @ 235
in/sec or greater

Altitude

Operating

-16 to 3048m (-50 to 10,000ft) Note: For
altitudes above 2950 feet, the maximum
operating temperature is de-rated 1°F/550ft

Storage

-16 to 10,600m (-50 to 35,000ft)

5.6 Power Consumption Testing

Table 6.

Power Consumption Testing

Feature

Energy Smart Power Supply High Output Power Supply

Dimensions

L-249 mm

1

x W-65.5 mm x H-38.2 mm

Status Indicators

1 x bi-color Light Emitting Diode

Integrated Fans

None

Fixed Input Plug

IEC-C14

AC Cord Rating

15 Amps @ 120 VAC, 10 Amps @ 240 VAC

Input Voltage

90–264 VAC

Auto-ranging

Yes

Line Frequency

47–63 Hertz

Maximum Inrush Current

55 Amps per supply for 10 ms or less

Hot-Swap Capability

Yes

Output Power

502 Watts

717 Watts

Maximum Heat Dissipation 1712.9 BTU per hour

2446.5 BTU per hour

Efficiency (20% – 100%
Load)

86.5–90% @ 115 VAC
88–92% @ 230 VAC

85–88.5% @ 115 VAC
86.5–90.5% @ 230 VAC