Installation – Avalon Firestyles Hideaway User Manual
Page 10

1 0
Installation
(for qualified installers only)
Travis Industries
4030612
1 0 0 - 0 1 1 4 8
Corner Installations
A typical 45° installation
uses the minimum framing
dimensions shown in the
illustration to the right
(NOTE: all clearances still
apply).
The recommended
dimensions shown to the
right allow additional
space, easing gas line
and electrical
connections.
1/2" Standoffs
5-1/2" Min.
6-1/2" Recommended
Min. 1/2"
Clearance
NOTE: do not insert any material into
the 1/2" gap along the front of the
fireplace.
22-1/4" Min.
24-7/8" Recommended
Raised Fireplaces
•
The fireplace (and
hearth, if desired) may
be placed on a platform
designed to support the
fireplace (125 Lbs.) and
vent.
•
The fireplace may not be
raised so as to place the
ceiling in front of the
fireplace within 57" of
the base of the fireplace.
Raised
Platform
Optional Hearth
Minimum
57"
Ceiling
Fireplace Enclosure
(min. 48")