Installation, Fireplace placement requirements, For qualified installers only) – Avalon Firestyles Hideaway User Manual

Page 9: Travis industries, Minimum framing dimensions, Clearances

Advertising
background image

Installation

(for qualified installers only)

9

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Fireplace Placement Requirements

Minimum Framing Dimensions

The fireplace requires a 1/2" space between the fireplace and the framing members (or other
materials) along the sides and back of the fireplace. These stand-offs may contact the framing
members but no material may be placed between the stand-offs.

Route the electrical line to a position

to the right rear of the fireplace.

Thermostat or Remote

Control Wire (either side)

If using an elbow directly off the fireplace,

the vent will be centered 41-3/4" above

the base of the fireplace.

1/2" Clearance to the front, 0" to the sides, 1" below,

and 2" above the vent to combustibles.

The fireplace enclosure must be a minimum

48" above the base of the fireplace. NOTE:

Do not build into the area above the

fireplace (except for the required framing

members).

20-1/4"

36"

48" Min.

15-1/2"

Firestop

(required)

HINT: We recommend installing the

shaded framing after the fireplace is in

place.

WARNING: A cut-out for the gas line will be

required on the framing. See the dimensions

on page 6 and "Gas Line Connection" for

details.

HINT: we recommend reinforcing the

upper corners of the fireplace opening.

6"

5"

1"

•

Fireplace must be installed on a level surface capable of supporting the fireplace and vent

•

Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)

•

Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.

•

This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.

Clearances

•

When installed, walls in front of the fireplace must be a minimum 1" to the side of the faceplate.

•

Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of the
fireplace (e.g. drapes, doors)

•

Fireplace must be placed so the vents below and above the glass do not become blocked