5121 touch down, 5122 plc not ready, Touch down – Avery Dennison Monarch 9864 Error Messages User Manual
Page 42: Plc not ready

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
42
5121 Touch
down
Status
The applied applicator does not reach the Touch Down Position. It extends
completely without reaching any product or other resistance.
Preconditions for this error to occur:
•
The parameter
DP INTERFACE > Interface type
is set to USI Applicator.
•
Internal inputs are enabled.
Action
Correct the applicator position. The applicator must reach the product
before it is completely extended.
Press Online to acknowledge.
5122
PLC not ready
Status
The connected PLC is not on line.
Preconditions for this error to occur:
•
The parameter
DP INTERFACE > Interface type
is set to USI Applicator.
•
Internal inputs are enabled.
Action
Check if the PLC is powered on.
Check if the PLC shows any error status.
Press Online to acknowledge.