Avery Dennison Monarch 9864 Error Messages User Manual
Page 44

05/08 Rev. AB
USER MANUAL
Error Messages
9844 – 9854 – 9864
44
•
Byte 2: xxxxxxxx
x
x
7 6 5 4 3 2 1 0
Reserved (must be 0):
Shows an error bit, which is provided
by the printer controller.
Reserved (must be 0):
Shows an error bit, which is provided
by the printer controller.
not used
not used
not used
Temperature sensor defective:
The Action at the A/D-converter
leads to a temperature below –20°C
or over +170°C. All outputs except
the logic supply are turned off.
Operation time counter:
Inconsistent data with the operation
time counter.
EEPROM error:
Data content of the EEPROM is not
consistent.
•
Byte 3: xxxxxxxx
x
x
(can only be 00H or F0H)
7 6 5 4 3 2 1 0
not used
not used
not used
not used
not used
not used
not used
I
2
C transfer error
•
Byte 4: xxxxxxxx (not used)
•
Example: 0000F020 means: "EEPROM error" and "Fan defective".