2 applicator modes, Applicator modes 10.2.1, Signals for direct dispense – Avery Dennison ALX 720 User Manual
Page 100: Alx 720, Operators manual, 1 signals for direct dispense

Operators Manual
ALX 720
4/09
Page 100
Connections and signals
10.2 Applicator modes
The machine is able to dispense the label direct
on the passing product. There is also the
possibility to drive without any external control a wide range of applicators.
10.2.1 Signals for direct dispense
For direct dispensing the airstream signal can be used to control a pneumatic driven dispensing
edge. The start of the airstream signal (= motor run signal) could be behind the start of the
dispense motor, adjusted with the function APT3. The signal is switched inactive, when the
label dispense has been completed. Also the stop could be adjusted with the function ASTP to
switch inactive before or behind the dispense motor stop.
Ready
Product start
Label start
Suppression
Product start
Suppression
Dispense
Motor run
signal
1
2
3
4
POS
POS
POS
PRDL
APT3
ASTP
ASTP
1
Productstart disabled. PRDL activ
2
Missing Label: New start of dispense during dispenser activ
3
Inhibit activ
4
Machine not ready. Errorcondition or not online
Figure 18 Timing diagram direct dispense