Motor Manufacturer Data

Motor manufacturer data should be reviewed before configuring the BE1-11m. Typical motor
manufacturer data is listed below.

●

GENERAL

○

HP .................................................................. 2900

○

Full-Load Amps (FLA) ................................... 363

○

Maximum Locked Rotor Current (LRA) ......... 600%

○

Bus Voltage ................................................... 4 kV

○

Service Factor................................................ 1.0

○

Stator Insulation Class ................................... F (155

°C per NEMA MG-1 Standard)

○

Ambient Temperature Rating ........................ 40

°C

○

Stator Temperature Rise ............................... 80

°C

○

Subtransient Reactance Xd” .......................... 0.15 pu, 2432 kVA base

●

RTDs

○

Six Stator RTDs ............................................. 100

Ω, 3-wire element, platinum

○

Two Bearing RTDs ........................................ 100

Ω, 3-wire element, platinum

○

One Ambient RTD ......................................... 100

Ω, 3-wire element, platinum

●

STARTING

○

Minimum Starting Voltage ............................. 85%

○

Hot Safe Stall Time ........................................ 9 seconds

○

Cold Safe Stall Time ...................................... 10 seconds

○

Rotor WK

2

...................................................... 410 lb-ft

2

●

CONSECUTIVE STARTS

○

Ambient Temperature .................................... 3 starts

■

Idle Starts Time ................................ 45 minutes

■

Running Starts Time ......................... 20 minutes

○

Operating Temperature ................................. 2 starts

■

Idle Starts Time ................................ 45 minutes

■

Running Starts Time ......................... 45 minutes

●

THERMAL TIME CONSTANT

○

Ambient (Stopped Condition) ........................ 75 minutes

○

Operating (Running Condition) ...................... 60 minutes

●

RUNNING

○

Ride Through Minimum Voltage .................... 75% for 60 seconds

○

Bearing Alarm Temperature .......................... 90

°C

○

Bearing Trip Temperature ............................. 95

°C

●

OPERATING PERFORMANCE

○

Load % ........................................................... 100 ...... 75 ........ 50

○

Amps .............................................................. 363 ...... 276 ...... 190

○

Efficiency % ................................................... 95.5 ..... 95.3 ..... 94.7

○

PF .................................................................. 90 ........ 89 ........ 87

●

OTHER

○

Name

○

Location

○

System Frequency

○

System Rotation

Settings Calculation Examples