Operating heater, Continued, Lighting instructions – Desa VP26T User Manual

Page 15

Advertising
background image

107887-01E

For more information, visit www.desatech.com

For more information, visit www.desatech.com

15

15

OPERATING HEATER (THERMOSTAT MODELS)

Lighting Instructions

OPERATING HEATER

Continued

1.

STOP! Read the safety information, column 2 page 14.

2.

Make sure equipment shutoff valve is fully open.

3.

Turn thermostat control knob clockwise

Clockwise

to the OFF

position (see Figure 22 or 23 for your model).

4.

Wait five minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow
“B” in the safety information, column 2 page 14. If you
don’t smell gas, go to the next step.

5.

Turn thermostat control knob counterclockwise

C-clockwise

to the PILOT position. Press in thermostat control knob
for 5 seconds (see Figure 22 or 23 for your model).

Note:

You may be running this heater for the first time

after hooking up to gas supply. If so, you may need to press
in thermostat control knob for 30 seconds or more. This
will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released,
contact a qualified service person or gas supplier for repairs.

6.

Keep thermostat control knob pressed in while pushing down
and releasing the ignitor button. This will light pilot. If nec-
essary, continue to press ignitor button until pilot lights.
If pilot does not light
• turn thermostat control knob clockwise

Clockwise

to the

OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, pages 19 through 21
• contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light
pilot with match, see Manual Lighting Procedure
, page 16.

7.

Keep thermostat control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7. This heater

has a safety interlock system. Wait one minute before light-
ing pilot again.

8.

Turn thermostat control knob counterclockwise

C-clockwise

to the desired heating level. For models, VP16T, VN18T,
VP26T, and VN30T, the main burner should light. Set con-
trol knob to any heat level between HI and LOW (see Fig-
ure 25). For infrastat models, the plaque directly above the
pilot should light.

LIGHTING

INSTRUCTIONS

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

IGNITOR

PILOT

LO

OFF

HI

Figure 22 - Control Knob In The OFF Position, Models VP16T,
VN18T, VP26T, & VN30T

Control
Knob

Ignitor
Button

Figure 24 - Pilot

Figure 25 - Burner Patterns

O

FF

HI

LO

PILOT

OFF

HI

LO

PILO

T

Control Knob

VP16T
VN18T

VP26T
VN30T

Figure 23 - Thermostat Control Knob In The OFF Position,
Models VP16IT, VN18IT, VP26IT, & VN30IT

IGNITOR

PIL

OT

LO

OFF

HI

1

2

3

4

Thermostat
Control Knob

Plaque Control Knob

Ignitor Button

Ignitor Electrode

Pilot Burner

Thermocouple

Advertising