2 product overview, 1 technical data – BECKHOFF KL5101-0000 User Manual
Page 5

Product overview
KL5101
3
2 Product overview
Signal - LEDs
Control - LEDs
Inputs A
Sensor
Supply
Inputs B
+ 24 V (2x)
Inputs C
0 V (2x)
Logic Inputs
Shield (1x)
Status Input
Top View
Contact Assembly
13
15
Ue
B
A
C
B
A
C
+
+
S
S
14
16
Uo
G1 G2
I1
5
C
D
6
7
8
1
A
B
2
3
4
Ue, Uo
+ 24 V
0 V
G 1, G 2
C, C
B, B
A, A
Status Input,Shield
2.1 Technical data
Technical data
KL5101-0000
KL5101-0012
Sensor connection
A, A(inv), B, B(inv), zero, zero(inv),
difference signal (RS 485); Status input
Sensor operating voltage
5 V DC
Sensor output current
0.5 A
Counter
16 bits binary
Cut off frequency
1 MHz (at 4 time evaluation)
Quadrature decoder
1-2-4 time evaluation
Zero pulse latch
16 bits
Commands
read, set, activate
Supply voltage
24 V DC (20 V ... 29 V)
Current consumption from power contacts
0.1 A (without sensor load current)
Bit width in the process image
I/O: 2 x 16 bits data, 1 x 8 bits control/status
Current consumption from K-Bus
25 mA
Weight approx..
85 g
Permissible ambient
temperature range
during operation
-25°C ... +60°C*
0°C ... +55°C
during storage
-40°C ... +85°C*
-25°C ... +85°C
Relative humidity
95%, no condensation
Vibration/shock resistance
conforms to EN 60068-2-6 / EN 60068-2-27
EMC resistance Burst / ESD
conforms to EN 61000-6-2 / EN 61000-6-4
Installation position
any
Type of protection
IP20
Approvals
CE, cULus, ATEX
CE
*) extended temperature range, but only
0°C ... +55°C (according to cULus for Canada and USA)
0°C ... +55°C (according to ATEX, see special conditions)