AX5801

2.3 Technical data

Product designation

AX5801-0000

AX5801-0200

Operating voltage of the relay (connections 1 to 4)

24 V

DC

(-15 % +20 %)

Operating voltage of the feedback contacts (5 and
6)

24 V

DC

(-15 % +20 %)

For the AX5000 servo drive

AX5000-xxxx-x0xx

AX5000-xxxx-x2xx

Max. switching current of the feedback contacts (5
and 6)

0.35 A

Conductor cross-section, connections 1 to 6

0.2 - 1.5 mm

2

(the use of wire end sleeves is recommended)

Strip length of the wires, connections 1 to 6

10 mm

Current consumption (total for both relays)

50 mA (typical)

Dimensions (W x H x D)

105 mm x 53 mm x 23 mm

Weight

approx. 85 g

Permissible ambient temperature (operation)

0 °C to +55 °C

Permissible ambient temperature
(transport/storage)

-25

to +70

Permissible air humidity

5 % to 95 %, non-condensing

Permissible air pressure
(operation/storage/transport)

750 hPa to 1100 hPa

Permissible level of contamination

Contamination level 2 according to EN 60204 / EN
50178

Impermissible operating conditions

TwinSAFE components must not be used under
the following operating conditions:

under the influence of ionizing radiation

in corrosive environments

in an environment that leads to
unacceptable soiling

EMC immunity/emission

according to EN 61000-6-2 / EN 61000-6-4

Protection class

IP20

Approvals

CE, TÜV SÜD

2.4 Safety parameters

Key figures

AX5801

PFH

2,47E-08

%SIL3

24,70%

MTTFd [a]

>100

B10

d

(cycles)

780 000

DC

>99%

Performance level

PL e

Category

4

HFT

1

Element classification*

Type A

*) Classification according to IEC 61508-2:2010 (see chapters 7.4.4.1.2 and 7.4.4.1.3)

To calculate the MTTFd value, a value of 8760 (1 operation per hour) was assumed for n