10

103685

PORTABLE FORCED AIR HEATERS

70,000 Btu/Hr H.S.I. Series

SERVICE
PROCEDURES

Continued

PUMP ROTOR

(Procedure if Rotor is Binding)

1.

Remove upper shell (see page 7).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover and air filters.

4.

Remove pump plate screws using 5/16"
nut-driver.

5.

Remove pump plate.

6.

Remove rotor, insert, and blades.

7.

Check for debris in pump. If debris is
found, blow out with compressed air.

8.

Install insert and rotor.

9.

Check gap on rotor. Adjust to .003"/
.004" if needed (see Figure 17).

Note:

Rotate rotor one full turn to in-

sure the gap is .003"/.004" at tightest
position. Adjust if needed.

10. Install blades, pump plate, air filters,

and filter end cover.

11. Replace fan guard and upper shell.

12. Adjust pump pressure (see page 7).

Note:

If rotor is still binding, proceed

as follows.

13. Perform steps 1 through 6 above.

14. Place fine grade sandpaper (600 grit)

on flat surface. Sand rotor lightly in
“figure 8” motion four times (see Fig-
ure 18).

15. Reinstall insert and rotor.

16. Perform steps 10 through 12 above.

TOR

PFA/P 056

Sandpaper

.003"/.004"
Gap
Measured
With
Feeler
Gauge

Blade

Rotor

Gap Adjusting Screw

Gap Adjusting Screw

Insert

Rotor

Air Output
Filter

Blade

Pump Plate

Air Intake Filter

Filter End
Cover

Fan Guard

Figure 16 - Rotor Location

Figure 17 - Gap Adjusting Screw
Locations

Figure 18 - Sanding Rotor

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Dept. at 1-800-323-5190.

When calling DESA International, have
ready:

• your name

• your address

• model number of your heater

• how heater was malfunctioning

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. Parts Centrals are listed in the
Authorized Service Center booklet supplied
with heater.

When calling DESA International, have
ready:

• model number of your heater

• the replacement part number

REPLACEMENT
PARTS

TECHNICAL
SERVICE

You may have further questions about op-
eration or troubleshooting. If so, contact
DESA International’s Technical Service
Dept. at 1-800-323-5190.

You can also visit DESA International’s
technical services web site at

www.desatech.com

.