Owner’s manual, Unpacking, Product identification – Desa B70D User Manual

Page 3: Theory of operation

Advertising
background image

3

103685

OWNER’S MANUAL

Figure 2 - Cross Section Operational View

Clean
Heated
Air Out

Figure 1 - 70,000 Btu/Hr

Handle

Fuel Cap

Lower Shell

Power Cord

Fuel Tank

Hot Air Outlet

Air Filter
End Cover

Fan Guard

Upper Shell

Side Cover

Ignition Control Assembly
(assembly on inside of side cover)

UNPACKING

1.

Remove all packing items applied to
heater for shipment.

2.

Remove all items from carton.

3.

Check items for shipping damage. If
heater is damaged, promptly inform
dealer where you bought heater.

PRODUCT IDENTIFICATION

The Fuel System:

The air pump forces

air through the air line. The air is then
pushed through the nozzle. This air causes
fuel to lift from the tank. A fine mist of fuel
is sprayed into the combustion chamber.

The Air System:

The motor turns the fan.

The fan pushes air into and around the
combustion chamber. This air is heated and
provides a stream of clean, hot air.

The Ignition System:

The ignition con-

trol assembly provides power to the ignitor.
This ignites the fuel/air mixture in the com-
bustion chamber.

The Flame-Out Control System:

This

system causes the heater to shut down if the
flame goes out.

Fuel
Filter

Air Line
To Burner

Air
Output
Filter

Air Pump

Air Intake
Filter

Cool
Air In

Fan

Combustion Chamber

Ignitor

Motor

Ignition Control
Assembly

Air For Fuel System

Air For Combustion
And Heating

Fuel

Nozzle

Fuel
Tank

THEORY OF OPERATION

Advertising