Technical data, Installation of the optional encoder card, Configuration via tcdrivemanager (idn-p-0-0180) – BECKHOFF AX570x User Manual

Page 3: Encoders and inputs

Advertising
background image

Seite 3/4

Technical data

Digital inputs “A” to “D”

(single-ended)

Open collector



max. 1 mA

Digital inputs “E” to “F”

(differential)

0 – 5 V

inp. resistance: 120 Ω

Installation of the optional encoder card

CAUTION

Caution – Do not work on live equipment!
Disconnect the equipment at all poles from live parts and secure it against being switched on again, so that there is no possibility of

uncontrolled movements of the equipment occurring.

DANGER

Caution – Danger of death!
Even when the AX5000 is disconnected from the mains voltage, dangerous voltage continues to be present at the "X02" terminals of

the DC link for 5 minutes. Never touch the terminals within this period.

Attention

Destruction of the optional encoder card through electrostatic charging!
The optional encoder card is an ESD-sensitive component. Follow the usual ESD safety procedures when handling the card (anti-

static wrist straps, earthing of the relevant components, etc.).


Fully release the bolt (1).

Remove the panel (2).

Carefully insert the optional card (3) into the opening in the direction of

the arrow. The slot has guides for the card on the short sides. Ensure

that the card is inserted into these guides.

Tighten the bolt (4).








Example: Renishaw RGH 22Z30D00 (TTL encoder with 2 parameter channels)

Configuration via TCDrivemanager (IDN-P-0-0180)

Encoders and inputs