XFC

Oversampling

Application Note DK9222-0213-0063

The following table gives an overview about the settings of the Video Binloop, which are not configured in TwinCAT but in the
external device.

SMPTE

Setting

Description

Value

Mode Determines whether the SMPTE Interface will

generate timecode, or read external timecode.

Gen

Frame rate

The frame rate in which SMPTE is generated.

23,976

Preroll Time

Initial time of SMPTE generator when it is first

enabled.

Start Time

Time that SMPTE generator returns to after it reaches

the end time (when looping)

00:00:00.00

End Time

Time when SMPTE generator either stops or loops

back to start time.

Loop Mode

Determines whether SMPTE generator loops

continuously from start to end time.

enabled

Powerup Mode

Determines whether SMPTE is enabled or disabled

when Binloop powers up.

Start

Restart Mode

Determines how SMPTE generator responds when it

is told to start again. It can either restart or ignore

the start command.

enabled

Idle Mode

Determines if SMPTE output is muted or active when

the SMPTE Interface is idle.

SMTPE Active

Determines how long SMPTE reader will free-wheel

when external SMPTE is lost.

disabled

Output Level

Configures the voltage level (in dB) of the SMPTE

output.

4 dBV

00:00:00.00

00:00:00.00

Self Gen Mode

Table 3 Binloop parameters (from manual at Alcorn McBride Inc. website) are not configured in TwinCAT

Note:

Theoretically the information is readable at all frame rates, but the sample program is designed for 24 fps and has not
been tested for other frame rates. Furthermore only the time information is read out, not the user bits, the flags and other
information transmitted with the frame.