Owner’s manual, Product identification, Local codes – Desa CGS2718N User Manual

Page 3: Unpacking product features, Safety information

Advertising
background image

3

107067

OWNER’S MANUAL

PRODUCT
IDENTIFICATION

Figure 1 - Yellow Flame Vent-Free Gas Log Heater Shown (Logs May Vary by Model)

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANS Z223.1
, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note:

Where listed vented decorative logs

are required, thermostat models are not per-
mitted.

UNPACKING

PRODUCT
FEATURES

OPERATION

This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic, dancing yellow flames. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANS Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. Non-thermostat models may also
be operated as a vented decorative (ANS
Z21.60) product by opening flue damper.

SAFETY PILOT

This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
shuts off the heater if there is not enough
fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.

WARNING: Do not remove

the metal Data Plates from the
grate assembly. The Data Plates
contain important product
information.

1.

Remove logs and heater base assem-
bly from carton.

Note:

Do not pick up

heater base assembly by burners. This
could damage heater. Always handle
base assembly by grate.

2.

Remove all protective packaging ap-
plied to logs and heater for shipment.

3.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.

Front Log

Control Knob

Back Log

Burner

Piezo
Ignitor

Crossover Log

SAFETY
INFORMATION

Continued

13. Do not operate heater if any log is bro-

ken. Do not operate heater if a log is
chipped (dime-sized or larger).

14. Turn heater off and let cool before ser-

vicing. Only a qualified service person
should service and repair heater.

15. Operating heater above elevations of

4,500 feet could cause pilot outage.

Advertising