8

107067

UNVENTED NATURAL GAS LOG HEATER

CGS2718N, CGS3124N,
CLD3018NA, and CLD3924NTA

INSTALLATION

Continued

Heat Resistant
Material

(A)

Minimum Noncombustible
Material Clearances

If Not Using Mantel

Note:

If using a mantel, proceed to If Using

Mantel. If not using a mantel, follow the
information below.

You must have noncombustible material(s)
above the fireplace opening. Noncombus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have noncombustible
material behind it. Noncombustible material
must extend at least 8" up (for all models). If
noncombustible material is less than 12", you
must install the fireplace hood accessory (24"
model only). See Figure 5 at right for mini-
mum clearances.

IMPORTANT:

If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation,
page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Noncombustible material okay.

Between 8" and 12"

24" Model: Install fireplace hood acessory (GA6050,

GA6052, or GA6053, see

Accessories, page 30).

18" Model: Noncombustible material okay.

Less than 8"

Noncombustible material must be extended to at
least 8". See

Between 8" and 12", above. If you

cannot extend material, you must operate heater
with flue damper open.

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

NOTICE: You may use non-ther-
mostat heater as a vented prod-
uct. If so, you must always run
heater with chimney flue damper
open. If running heater with
damper open, noncombustible
material above fireplace opening
is not needed. Go to

Installing

Damper Clamp Accessory for
Vented Operation, page 10

If Using Mantel

You must have noncombustible material(s)
above the fireplace opening. Noncombus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have noncombustible
material behind it. Noncombustible mate-
rial must extend at least 8 inches up (for all
models). If noncombustible material is less
than 12", you must install the fireplace hood
accessory (24" model only). Even if non-
combustible material is more than 12", you
may need the hood accessory to deflect heat
away from your mantel shelf. See Figure 5
and Figures 6 and 7 on page 9 for minimum
clearances.

IMPORTANT:

If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation,
page 10.

Advertising