Possible Causes

What To Do

NO HEAT AND NO “ON” INDICATOR LIGHT.

Unit not plugged in or wall electrical breaker is
tripped.

Plug unit in and / or check electrical outlet.

NO HEAT WITH “ON” INDICATOR LIGHT ON.

Loose wire.

Check wires.

Heating element failure

Check heating element for open circuit or short .
Replace if defective.

Defective time delay relay.

Replace time delay relay.

Defective infinite switch.

Replace infinite switch.

UNEVEN ICING TEMPERATURE.

Icing needs stirring.

Stir icing.

LOW HEAT AFTER TWO HOURS ON (HEAT LIGHT CYCLING ON AND OFF).

Infinite switch setting is to low.

Readjust infinite switch setting through the hole at
the end of the heating conveyor panel.

LOW HEAT AFTER ONE HOUR ON (HEAT LIGHT CYCLING ON AND OFF).

Time delay relay is set to low.

Increase the time delay relay setting.

TO HIGH OF HEAT AFTER TWO HOURS ON .

Infinite switch setting to high.

Readjust infinite switch setting at the end of the
heating corner panel.

Defective infinite switch.

Replace switch if the heat on cycle light does not
cycle after one hour.