Beurer LB 50 User Manual

Page 21

Advertising
background image

19

7

IN THE EVENT OF PROBLEMS

Problem

Cause

Remedy

No steam
exiting

Appliance not connected to power

Insert the plug [14] into the
mains and switch on the
appliance.

Water tank [8] empty.

Replenish water.

Water tank [8] not fitted correctly.

Fit tank properly.

Appliance
leaking

Water tank [8] leaking.

Replace tank.

Water tank [8] not shut properly.

Fasten the catch properly.

Steam tower [3] not installed or not
installed correctly.

Install steam tower [3]
properly.

Delay in steam
output

Very cold water in tank.

Use warmer water.

Appliance heavily scaled.

Descale the appliance.

Red indicator
[A] illuminated

Water tank [8] empty.

Replenish water.

Valve on tank catch [9] is covered
with dirt.

Clean the valve.

Appliance heavily scaled.

Descale the appliance.

Water tank [8] not shut properly.

Close the catch properly.

Water tank [8] not fitted correctly.

Fit tank properly.


If the problem persists, please contact customer service.

8 T

ECHNICAL DETAILS

Rated output

380 W

Nominal voltage

230 V / 50 Hz

Water tank volume

approx. 5 litres

Evaporation rate

• Level 1: 150 ml/h
• Level II: 400 ml/h

Overheating protection

Through thermostat

Safeguard against running dry

If there is not enough water in the heater unit, the
appliance switches off automatically. The appliance has
a sensor which detects the water level.

Switching 2-stage

Weight 2.8

kg

Dimensions (W / H / D)

235 / 315 / 280 mm

Connection

Fixed cable, approx. 2 m in length