Rear panel – BSS Audio BLU-GPX Owner's Manual User Manual

Page 6

Advertising
background image

6

Rear Panel

Primary Power

These two PoE-enabled Ethernet ports are used for system communications and for

providing primary power to the BLU-GPX.
Secondary Power

This 12VDC connector is provided for power source backup. The front panel ‘Power

Supply’ LED provides convenient indication of power

supply status.
NOTE: The BLU-GPX Default Control Panel also provides

visual feedback regarding whether the device is powered

via PoE (‘Primary Power’) or the DC input (‘Secondary

Power’).
NOTE: These models shall be powered by a certified AC/DC power adaptor from FranMar

International Inc., Model FRA030E-S12-4, rated 100-240V~, 50-60 Hz, 0.7A, Class I (for

rated 12Vdc) or powered by certified POE Limited Power Source Adaptor from SL Power,

Model PW180KA4800F01, rated 100-250V~, 50-60Hz, 0.5A, Class I (for rated 48Vdc).
Locate

Pressing the LOCATE switch on the rear of the unit will illuminate the LOCATE switch

on the front and identify the device within London Architect. Similarly the switch will

illuminate if the device is selected from within London Architect or from the LOCATE

switch on the front panel.
RS232

Serial port for connection of external control equipment.
Control Inputs 1-36

These CONTROL INPUTS can be connected to contact closures for controlling binary

parameters, resistor ladders for controlling multi-state parameters, or potentiometers for

controlling continuous parameters, e.g. BLU-3 selector wallplate (Part no. Z-BLU-3). The

BLU-GPX has 47 Common (ground) connections (labelled ‘C’). A multiplicity of Common

connections results in simplified wiring to and from external equipment, reducing the

need to span connections across terminal block connectors. The control ports have two

modes of operation: 2-wire and 3-wire. Provided are 12 Reference connections (Labelled

‘R’) which facilitate 3-wire mode operation.
Logic Outputs 1-23

These 23 Logic Outputs are used to connect ‘tally’ indicator LEDs or relays.
Each Logic Output produces 0V or +5V DC via an internal 440 Ohm resistor and

accompanying internally connected common (ground) connection (C).
An LED connected between one output (Anode, A) and common (Cathode, K) will

illuminate when the LOGIC OUTPUT is activated, without requiring any external current

limiting resistor.
A high sensitivity relay (such as a reed relay) may be driven by connecting four outputs in

parallel. This arrangement will develop 4V across a 500-Ohm coil, providing that all four

outputs are made logic 1 simultaneously.
Opto Output

The last output located on the ‘LOGIC OUTPUTS 13-23’ terminal block is labelled ‘O’.

This is the OPTO OUTPUT, an isolated output which fails safe (open circuit) if the unit

becomes faulty.

Advertising