Location of internal jumpers, etc, Factory default jumper settings – Cloud Electronics MPA60 User Manual

Page 13

Advertising
background image

MPA Series User Manual v1.2

13

Location of internal jumpers, etc.

FAN

J1

J5A &

J5B

J6

J8

J10

(below ribbon cable)

J14

BOSE EQ

CARD SOCKET

REAR OF AMPLIFIER

MPA SERIES: MAIN PCB.

TOP VIEW. ONLY PRIMARY

COMPONENTS SHOWN.

J2

J3

J4

J11

J12

(under sub-board)

J13

J9

J7

NOT TO SCALE

CON8

CHIME

VOLUME CONTROL

fig.7: Internal jumpers

Factory Default Jumper Settings

Jumper

Function

Default Setting

J1

Mic 1 access triggers chime

OFF

J2

65 Hz high pass filter frequency

ON

J3

EQ card socket bypass

ON

J4

Front panel source select switch disable

SW

J5 (A & B)

Line input 6 priority

OFF

J6

Mic over music priority (VOX function)

ON

J7

Line 6 priority release time 3, 6 or 12 seconds

3S

J8

Mic 1 priority over Mics 2, 3 & 4

OFF

J9

Mic 1 phantom power

OFF

J10

Mic 2 phantom power

OFF

J11

Mic 3 phantom power

OFF

J12

Mic 4 phantom power

OFF

J13

Mic 1 Access Input bypass

ON

J14

Music Mute NO or NC

NO

Advertising