Bs en 55103-1:1997, Bs en 55103-2:1997, Bs en 60065:1998 – Cloud Electronics Matrix4 User Manual

Page 9: Safety considerations and information, Caution – servicing, Caution – installation, Caution - mains fuse, 22 general specifications, Microphone inputs, Outputs

Advertising
background image

8

Matrix 4 I

NSTALLATION AND OPERATION MANUAL

16/12/02 V6.0



Microphone Inputs

Frequency Response

100Hz / -3dB(filter), 20kHz

±0.5dB

Distortion <0.05%

20Hz-20kHz

Gain Range

-60dB

Input Impedance

>2k

Ω (balanced)

Common mode rejection

>70dB 1kHz

Headroom >20dB
Noise

-120dB EIN 22Hz-22kHz (150

Ω)

Equalisation

HF:

±10dB/5kHz LF: ±10dB/100Hz

Outputs

775mV (0dBu) balanced (3 pin male XLR)

22 General

Specifications

Power input

230V

±10% (internal adjustment for 115V)

Fuse rating

T100mA H for 230V supply T200mA H for 115V supply

Fuse type

20mm x 5mm class 250V

Dimensions (cm)

48.260 x 13.25(3U) x 15 deep (+ con)

Weight (kg)

4.10 net

This product conforms to the following European EMC Standards:

BS EN 55103-1:1997
BS EN 55103-2:1997

This product has been tested for use in commercial and light industrial environments. If the equipment
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded.

The product conforms to the following European electrical safety standard.

BS EN 60065:1998

Safety Considerations and Information

The unit must be earthed. Ensure that the mains power supply provides an effective earth
connection using a three-wire termination. When the mains switch is in the off ‘O’ position the
live and neutral conductors of the mains transformer are disconnected.

CAUTION – Installation

Do not expose the unit to water or moisture.

Do not expose the unit to naked flames.

Do not block or restrict any air vent.

Do not operate the unit in ambient temperatures above 35

o

C.

CAUTION - Mains Fuse

Replace the mains fuse only with the same type and rating as marked on the rear panel. The

fuse body size is 20mm x 5mm.

CAUTION – Servicing

The unit contains no user serviceable parts. Refer servicing to qualified service personnel. Do

not perform servicing unless you are qualified to do so.

Disconnect the power cable from the unit before removing the top panel and do not make any

internal adjustments with the unit switched on.

Only reassemble the unit using screws identical to the original parts.

In the interest of continuing improvements Cloud Electronics Limited reserves the right to alter

specifications without prior notice.

Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England

Telephone +44 (0) 114 244 7051 Fax +44 (0) 114 242 5462 E-mail: [email protected]

Advertising