CDM-600/600L Open Network Satellite Modem
Revision 3
Front Panel Operation
MN/CDM600L.IOM
5–30
5.4.12 CONFIG: IMPEDANCE (CDM-600 ONLY)
IF IMPEDANCE = 50 (50,75 OHMS)
Select 50 or 75 using the [
↑][↓] arrow keys, then press [ENT]. Note that this affects both the Rx
and Tx IF ports simultaneously.
5.4.13 CONFIG: STATISTICS
LINK STATISTICS LOGGING INTERVAL:
10 MINUTES (00 to 90)
(
v)
The Logging Interval is the period of time over which the performance statistics will be
measured. Set the logging interval – 10 through 90 minutes in 10-minute increments – using the
[
↑][↓] arrow keys, then press [ENT]. Setting a value of 00 disables the feature (no logging).
For more information about the Statistics data taken, refer to Section 5.7.3 MONITOR:
STATISTICS.
To view the Statistic log information, from the ‘SELECT: (Main)’ menu, go to ‘MONITOR:
STATISTICS’.