CDM-625 DC-AC Conversion Instructions with IP Packet Processor
MN-625DCACIPFRI Rev A
Page 3 of 4
Copyright © Comtech EF Data Corporation, 2012. All rights reserved.
4. Remove the DC power supply, power harness and DC filter.
IMPORTANT: If there are standoffs under the power supply, remove them and install the
provided standoffs (HW/STF440MFS303). If there are NO standoffs under the power supply,
DO NOT install the provided standoffs.
5. Install new AC power supply (PS-0000065), power harness (CA-0000564), new ground cable
(PL/6140), insulator cover paper (FP/8393-1), high voltage label (LB/DNGR-HV40X28) and AC
input filter (PL-0000852). See pictures below.
Install
Remove
O
= Standoff