Comtech EF Data MIDAS Version 4.X NMS Configuration User Manual
Page 75

MIDAS 4.X NMS Configuration, Rev.6
Setup and Operation 2–47
If a value of zero is entered for the Carrier Loss Timeout, the node controller will use its
default value of two seconds.
IMPORTANT
The following screen is only applicable to EF Data Type SDM-modems.
Automatic Uplink Power Control can only be viewed when channel is Inactive. For
Comtech EF Data CDM-modems, the N/A Sections will be ‘GREYED’ out.
AUPC Settings
Comtech Modem
Parameter
Range
Default
Range
Default
Max Power (delta from
nominal)
+3 to +20 db
+10 db
O to 9 dB
1
Min Power (delta from
nominal)
-3 to -20 db
-10 db
N/A
3
Target Eb/N0
3.2 to 16.0 db
12 db
0 to 9 .9 dB
Max Tracking Rate
0.5 to 6.0 db/min
2.0 db/min
N/A
Carrier Loss Local Action
(Hold,Nominal,Max)
Max
N/A
Carrier Loss Remote Action (Hold,Nominal,Max)
Max
Nominal, Max
Nominal, Max
Carrier Loss Timeout
0 to 255 sec
0
0 to 255
0