Specifications (preliminary), 4 specifications (preliminary), Pecifications – Comtech EF Data CRS-400 User Manual
Page 23: Reliminary
Advertising

CRS-400 1:8 Redundancy Switch
Revision 0
Introduction
MN/CRS400.IOM
7
1.4 S
PECIFICATIONS
(P
RELIMINARY
)
Characteristic Requirement
AC Prime Power
Two independent inputs,
90 to 264 VAC; 50/60 Hz;
at 25 Watts
Size/Weight
Data
Switch/Control
Unit
IF Switch Unit
4U 19 in. by 20.1 in. deep, Rack Mount
(4U 48.26 cm W by 51.054 cm D)
< 20 pounds (< 9.07 kg)
4U 19 in. by ~4.5 in. deep, Rack Mount
(4U 48.26 cm W by 11.43 cm D)
< 10 pounds (<4.54 kg)
Environmental
Temperature
Humidity
0 to +40
°
C Operating
-50 to +100
°
C Storage
95% at +40
°
C, Non-condensing
EMC And Safety
EN 55022 Class B emissions
EN 50082-1 immunity
EN 60950 Safety
FCC Part 15 Class B
Advertising