1.1 Overview

A complete redundant system consists of:

•

RC-1160 or RC-1260 redundancy switch controller

•

Redundant amplifier plate with two or three LNA/LNBs

•

Interconnect cable up to 1500 feet (457 meters) in length

The redundancy switch controller performs the following functions:

•

Supplies +14V power to the LNA/LNBs.

•

Measures LNA/LNB current.

•

Performs calibration on LNA/LNB current.

•

Signals a fault with abnormal current deviation.

•

Sounds audio alarm on fault (can be disabled).

•

Switches LNA/LNB on a priority basis in auto mode.

•

Controls waveguide and coaxial switch position.

•

Provides FORM-A and FORM-C relay contacts for remote status.

•

Provides a 9-pin EIA-485/-232 serial interface.

•

Normal/maintenance switch online during servicing.

Advertising