3 interface, Configuration, Commands – Comtech EF Data CDM-IP 300L User Manual

Page 129

Advertising
background image

CDM-IP 300L IP-Centric Satellite Modem

Rev. 1

CD/CDMIP300L.IOM

103

Parameter

Type

Protocol

Description

LNB Power

Command:
Response:

Status:
Response:

<add/LNB_xxx'cr'
>add/LNB_xxx'cr''lf']

<add/LNB_'cr'
>add/LNB_xxx'cr''lf']

Where: xxx = ON or OFF.

LNB Voltage

Command:
Response:

Status:
Response:

<add/LNBV_xxx'cr'
>add/LNBV_xxx'cr''lf']

<add/LNBV_'cr'
>add/LNBV_xxx'cr''lf']

Where: xxx = 13,18, or 24 Volts

LNB
Reference
Enable

Command:
Response:

Status:
Response:

<add/LNBR_xxx'cr'
>add/LNBR_xxx'cr''lf']

<add/LNBR_'cr'
>add/LNBR_xxx'cr''lf']

Where: xxx = ON or OFF.

LNB Power
Monitor Low
Current
Threshold

Command:
Response:

Status:
Response:

<add/LNBL_xxx'cr'
>add/LNBL_xxx'cr''lf']

<add/LNBL_'cr'
>add/LNBL_xxx'cr''lf']

Where: xxx = 0 to 500 in 1 mA steps

LNB Power
Monitor High
Current
Threshold

Command:
Response:

Status:
Response:

<add/LNBH_xxx’cr’
>add/LNBH_xxx’cr’’lf’]

<add/LNBH_’cr’
>add/LNBH_xxx’cr’’lf’]

Where: xxx = 0 to 500 in 1 mA steps

5.4.3 I

NTERFACE

C

ONFIGURATION

C

OMMANDS

Parameter

Type

Protocol

Description

Interface
Transmit
Overhead
Type

Command:
Response:

Status:
Response:

<add/ITOT_xxxxx'cr'
>add/ITOT_xxxxx'cr''lf']

<add/ITOT_'cr'
>add/ITOT_xxxxx'cr''lf']

Where: xxxxx = NONE*




*Note: TE: CDM-IP 300L only

Interface
Receive
Overhead
Type

Command:
Response:

Status:
Response:

<add/IROT_xxxxx'cr'
>add/IROT_xxxxx'cr''lf']

<add/IROT_'cr'
>add/IROT_xxxxx'cr''lf']

Where: xxxxx = NONE*




*Note:

CDM-IP 300L only

External
Clock-
Reference
Frequency

Command:
Response:

Status:
Response:

<add/ERF_nnnnn.n'cr'
>add/ERF_nnnnn.n'cr''lf']

<add/ERF_'cr'
>add/ERF_nnnnn.n'cr''lf']

Where: nnnnn.n = 8.0 to 10000.0 (external clock frequency in
kHz).

Advertising