Comtech EF Data SDM-300L User Manual
Page 52

SDM-300L Satellite Modem
Operation
Rev. 2
3–11
SDM300L "TYPE"
VER: X.X.X
FUNCTION SELECT
CONFIGURATION
CONFIGURATION
LOCAL AUPC
(AUPC option only)
AUPC ENABLE
NOMINAL POWER
MINIMUM POWER
MAXIMUM POWER
TARGET NOISE
TRACKING RATE
LOCAL CL ACTION
REMOTE CL ACTION
ON
OFF
-5.0 to -30.0 dBm
(In 0.5 dBm steps)
[0 to -40.0 TX/RX L-Band Only]
3.2 to 16.0 dB
(In 0.1 dB steps)
0.5 to 6.0 dBm/min
(In 0.5 dBm/min steps)
HOLD
NOMINAL
MAXIMUM
-5.0 to -30.0 dBm
(In 0.5 dBm steps)
[0 to -40.0 TX/RX L-Band Only]
-5.0 to -30.0 dBm
(In 0.5 dBm steps)
[0 to -40.0 TX/RX L-Band Only]
HOLD
NOMINAL
MAXIMUM
ACCESS TO
SUBMENU
CONDITIONAL OR
OPTION-DEPENDENT
Parameter Information
Key:
Figure 3-7. Configuration Local AUPC Menu
Notes:
1. Used for ASYNC/AUPC option and for self-monitoring local AUPC control.
2. Manufacturer does not recommend the tracking noise ( E
b