3.2.1.3 UNIT 1 COMM (J3)
The J3 UNIT 1 COMM connector is used for connecting the MBT-4000
Base Module Unit 1 section to the J6 COMM connector featured on both the
BUC-4000 Block Up Converter and BDC-4000 Block Down Converter
Modules via the 15-15 Power & Signal Harness (CEFD P/N
CA/WR10963-1), as shown in Figure 3-2.
Table 3-4. UNIT 1 COMM (J3) Connector Pinouts
Pin
Signal
A SUM
FLT
M RxD
BXC
C Tx+
BXC
D GND
E +7.5V
F +7.5V
G +15V
H GND
J Rx+
BXC
K Rx-
BXC
L Tx-
BXC
B TxD
BXC
N SPARE
P
10 MHz REF
R SPARE
NOTE – Mating Connector:
CEFD P/N CN/8LT5-15B15PN
Figure 3-2. Unit 1 Base Module to Converter Module Connection