AA.5.5.3.3 Config | Rx Page
Use this page to configure the Receive (Rx) operational settings for the unit. At any time, click
Refresh to update this page and see the most recent data.
Figure AA-8. Config | Rx page
Rx Attenuation
Enter a numeric value from 00.00 to 20.00 to set the receive attenuation in dB. The default
value is 10.00. Click Change to save the setting.
Mute
Use the drop-down list to select Disabled or Enabled for the receiver mute. Click Change to save
the setting.
Slope Mode
Use the drop-down list to select Manual or Calibrated. Click Change to save the setting.
Slope Adjust
Enter a numeric value from 0.0 to 1.0 to set the slope adjust. Click Change to save the setting.
Frequency (MHz)
Enter a numeric value from 3625.0 to 4200.0 for a standard unit to set the receive frequency in
MHz. The default value is 3400.0 MHz. Click Change to save the setting.