3 16 watt sspa connections – Comtech EF Data KST-2000A/B User Manual
Page 42
Advertising

Ku-Band Satellite Transceiver
Revision 9
Installation
MN/KST2000AB.IOM
2–14
2.4.2.3
16 Watt SSPA Connections
The 16 Watt SSPA input and output connections are shown in Figure 2-4
Figure 2-4. 16Watt SSPA
Note: When replacing fuses in the 16 Watt SSPA, use 6.3 amp, 3AG fuses, (2 each).
AC Line Input Connector (J3)
AC Power Connection
Pin
Function
Color
A Line
Brown
B Neutral Blue
C Ground Green/Yellow
Mating connection is molded power cord
Comtech PN
CA/84914-0223
Optional –48V DC DC Power
Connection
Pin
Function
A +
VDC
B Ground
C -
VDC
D No
Connect
Mating connector is a Comtech P/N
CN/STPG04F01(Amphenol PT06E-12-
4S(SR))
AC IN
GND
ERDE
J1
RF IN
J2
M/C
Advertising