Seer, Cooling performance with evaporator coils, 2hp13 split system heat pump – Ducane (HVAC) 2HP13 User Manual
Page 3
2HP13 Split System Heat Pump
2HP13 Split System Heat Pump
seer
13
seer
13
Cooling Performance with Evaporator Coils
Outdoor
Model
Indoor Model
Cooling
Heating
Refrigerant
Connection
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor
Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
SEER
EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
HSPF
47°
17°
CFM
Suction
Liquid
Suction
Liquid
Btuh
COP
Btuh
COP
2HP13**18P
E(C,H,M,U)1P36(A,B,C)+TXV
E(C,H,M,U)2T36(A,B,C)
13.00
12.00
19,000
15,000
7.70
18,000
2.88
11,900
1.84
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
2HP13**24P
E(C,H,M,U)1P29A+TXV
E(C,H,M,U)2T29A
13.00
11.50
24,000
19,700
7.70
22,000
2.88
13,400
2.18
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36(A,B,C)+TXV
E(C,H,M,U)2T36(A,B,C)
13.00
11.50
24,400
19,700
7.70
22,600
2.88
13,400
2.22
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
2HP13**30P
E(C,H,M,U)1P36(A,B,C)+TXV
E(C,H,M,U)2T36(A,B,C)
13.00
11.00
29,000
23,800
7.70
25,800
3.30
15,900
2.14
1085
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
2HP13**36P
E(C,H,M,U)1P43B
E(C,H,M,U)2T43B
13.00
11.00
35,000
25,800
7.70
35,000
3.00
21,800
2.04
1250
3/4
3/8
7/8
3/8
3/4
3/8
.076
H2TXV01
E(C,H,U)1P49C
E(C,H,U)2T49C
13.00
11.00
35,000
25,800
7.70
35,000
3.00
21,800
2.04
1250
3/4
3/8
7/8
3/8
3/4
3/8
.076
H2TXV01
2HP13*42P
E(C,H,U)1P49C
E(C,H,U)2T49C
13.00
12.00
40,000
30,000
7.70
38,000
3.06
21,800
2.38
1450
7/8
3/8
7/8
3/8
7/8
3/8
.076
H2TXV02
E(C,U)1P60D
E(C,U)2T60D
13.00
12.00
40,000
30,000
7.70
38,000
3.06
22,000
2.38
1450
7/8
3/8
7/8
3/8
7/8
3/8
.076
H2TXV02
EH1P49D
---
13.00
12.00
40,000
30,000
7.70
38,000
3.06
21,800
2.38
1450
7/8
3/8
7/8
3/8
7/8
3/8
.076
H2TXV02
2HP13*48P
E(C,H,U)1P49C
E(C,H,U)2T49C
13.00
11.50
46,000
34,500
7.70
45,000
2.96
29,400
2.28
1650
7/8
3/8
7/8
3/8
7/8
3/8
.082
H2TXV02
E(C,H,U)1P62D
E(C,H,U)2T62D
13.00
11.50
46,500
35,000
7.70
45,500
2.96
30,000
2.32
1650
7/8
3/8
7/8
3/8
7/8
3/8
.082
H2TXV02
2HP13*60P
E(C,H,U)1P62C
E(C,H,U)2T62C
13.00
11.50
56,000
40,900
7.70
54,000
3.40
32.000
2.58
1950
7/8
3/8
7/8
3/8
1-1/8
3/8
.098
H2TXV02
E(C,H,U)1P62D
E(C,H,U)2T62D
13.00
11.50
54,000
39,400
7.70
52,000
3.40
31,600
2.54
1950
7/8
3/8
7/8
3/8
1-1/8
3/8
.098
H2TXV02
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.
** - B, L, BC, LC
* - B, L