Seer, 2hp13 split system heat pump – Ducane (HVAC) 2HP13 User Manual
Page 4
2HP13 Split System Heat Pump
seer
13
** - B, L, BC, LC
* - B, L
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.
Outdoor
Model
Indoor Model
Variable
Speed
Furnace
Cooling
Heating
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor
Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
SEER
EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
HSPF
47°
17°
CFM
Suction
Liquid
Suction
Liquid
Btuh
COP
Btuh
COP
2HP13**18P
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG80*C***V12B
14.00
13.00
19,000
15,000
7.7
17,600
3.00
11,500
1.90
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG95*C***V12B
14.00
13.00
19,000
15,000
7.7
17,600
3.00
11,500
1.90
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M18C****P
---
---
13.00
12.50
18,000
14,200
7.7
17,000
3.50
8.800
2.20
650
3/4
3/8
3/4
3/8
3/4
3/8
.055
H2TXV01
RBCS2M18C****P+TXV
---
---
13.00
12.50
18,000
14,200
7.7
17,000
3.50
9,700
1.86
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M18C****T
---
---
13.00
12.50
18,000
14,200
7.7
17,000
3.50
9,700
1.86
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M24C****P+TXV
---
---
13.00
12.50
18,000
14,200
7.7
17,000
3.50
9,700
1.86
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M24C****T
---
---
13.00
12.50
18,000
14,200
7.7
17,000
3.50
9,700
1.86
650
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M24V****P
---
---
14.00
13.50
18,200
14,400
8.0
16,800
3.70
8,500
2.20
650
3/4
3/8
3/4
3/8
3/4
3/8
.055
H2TXV01
2HP13**24P
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG80*C***V12B
14.00
12.50
24,400
19,700
7.7
22,000
3.00
13,000
2.30
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG80*C***V14B
14.00
12.50
24,400
19,700
7.7
22,000
3.00
13,000
2.30
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG95*C***V12B
14.00
12.00
24,400
19,700
7.7
22,000
3.00
13,000
2.30
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG95*C***V14B
14.00
12.00
24,400
19,700
7.7
22,000
3.00
13,000
2.30
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M24C****P
---
---
13.00
11.50
24,000
19,700
7.7
21,400
3.20
13,400
2.20
850
3/4
3/8
3/4
3/8
3/4
3/8
.063
H2TXV01
RBCS2M24C****P+TXV
---
---
13.00
11.50
24,000
19,700
7.7
21,400
3.34
13,400
2.22
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M24C****T
---
---
13.00
11.50
24,000
19,700
7.7
21,400
3.34
13,400
2.22
850
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M24V****P
---
---
14.00
12.50
24,400
19,700
8.0
21,000
3.50
13,000
2.30
850
3/4
3/8
3/4
3/8
3/4
3/8
.063
H2TXV01
2HP13**30P
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG80*C***V12B
14.00
12.00
29,000
23,800
7.7
25,200
3.50
15,500
2.20
1085
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG80*C***V14B
14.00
12.00
29,000
23,800
7.7
25,200
3.50
15,500
2.20
1085
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG95*C***V12B
14.00
11.50
29,000
23,800
7.7
25,200
3.50
15,500
2.20
1085
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
E(C,H,M,U)1P36B+TXV
E(C,H,M,U)2T36B
CG95*C***V14B
14.00
11.50
29,000
23,800
7.7
25,200
3.50
15,500
2.20
1085
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M30C****P
---
---
13.00
11.00
28,000
21,700
7.7
27,000
3.40
15,200
2.20
1050
3/4
3/8
3/4
3/8
3/4
3/8
.068
H2TXV01
RBCS2M30C****P+TXV
---
---
13.00
11.00
28,000
21,700
7.7
27,000
3.40
15,200
2.04
1050
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M30C****T
---
---
13.00
11.00
28,000
21,700
7.7
27,000
3.40
15,200
2.04
1050
3/4
3/8
3/4
3/8
3/4
3/8
---
H2TXV01
RBCS2M36V****P
---
---
14.00
12.00
28,400
22,000
8.0
26,600
3.60
15,000
2.20
1050
3/4
3/8
3/4
3/8
3/4
3/8
.068
H2TXV01
Cooling Performance with Air Handlers and Furnaces 18, 24, 30