Desa BY150CE User Manual

Page 17

Advertising
background image

17

102422

Pump Rotor

(Procedure if rotor is binding)

1. Remove upper shell (see

page 10).

2. Remove filter end cover

screws using 5/16" nut-
driver.

3. Remove filter end cover

and air filters.

4. Remove pump plate

screws using 5/16" nut-
driver.

5. Remove pump plate.
6. Remove rotor, insert, and

blades.

7. Check for debris in pump.

If debris is found, blow
out with compressed air.

8. Install insert and rotor.
9. Check gap on rotor.

Adjust to .076/.101 mm
(.003"/.004") if needed
(see Figure 27).

Note:

Rotate rotor one

full turn to insure the gap is
.076/.101 mm (.003"/.004") at
tightest position. Adjust if
needed.

10. Install blades, pump plate,

air filters, and filter end
cover.

11. Replace fan guard and

upper shell.

12. Adjust pump pressure (see

page 14).

Note:

If rotor is still binding,

proceed as follows.

13. Perform steps 1 thru 6

above.

14. Place fine grade sandpaper

(600 grit) on flat surface.
Sand rotor lightly in
“figure 8” motion four
times (see Figure 28).

15. Reinstall insert and rotor.
16. Perform steps 10 thru 12

above.

Figure 25 - Rotor Location, 30/70,000 Btu/Hr Models

Sandpaper

Figure 28 - Sanding Rotor

Gap Adjusting
Screw

Gap
Adjusting
Screw

Blade

Figure 27 - Gap Adjusting
Screw Locations

Figure 26 - Rotor Location, 90/150,000 Btu/Hr Models

Insert

Blade

Rotor

Pump
Plate

Air Intake
Filter

Air
Output
Filter

Pump
Plate

Insert

Rotor

Blade

Filter End
Cover

Air
Intake
Filter

Air Output
Filter

Fan Guard

.076/.101 mm (.003"/.004") Gap
Measured With Feeler Gauge

Rotor

Fan Guard

Filter End
Cover

Advertising
This manual is related to the following products: