9

102422

TROUBLE-

SHOOTING

Wrong pump pressure

Dirty air output, air intake,
and lint filters

Dirty fuel filter

Dirt in nozzle

Dirty photocell lens

Bad flame-out control

See Pump Pressure

Adjustment, page 14.

See Air Output, Air Intake

and Lint Filters, page 14.

See Fuel Filter, page 11.

See Nozzle, pages 15 and

16.

Clean photocell lens.

Replace flame-out control.

WARNING

Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.

Heater will not
ignite, but motor runs
for a short period of
time.

Wrong pump pressure

Carbon deposits on spark

plug and/or improper gap

Dirty fuel filter

Dirt in nozzle

Water in fuel tank

Electronic ignitor not

grounded (earthed)

Bad electronic ignitor

See Pump Pressure

Adjustment, page 14.

See Spark Plug, pages 12

and 13.

See Fuel Filter, page 11.

See Nozzle, pages 15 and

16.

Drain and flush fuel tank

with clean kerosene.

See Storing, Transport-

ing, or Shipping, page 8.

Make sure electronic

ignitor mounting is tight.

Replace electronic

ignitor.

WARNING: High voltage!

Flame-out control not reset

Binding pump rotor

Motor does not start
when heater is
plugged in, fan
rotates slowly or
does not turn.

Reset flame-out control

button, see Figures 5 and
6, page 7.

If fan is hard to turn, see

Pump Rotor, page 17.

Advertising