10

Electrical Installation

BB-2117 & BB-2119 Power/Signal Connection

Route the interconnect cable (P51) located in the left side of the BB-2117/BB-2119 up through
the hole in the top of the cabinet into the hole in the bottom of the BB-2116 and connect to a
mating interconnect cable (J51).

3.5 Statistics Display & Hockey Module Signal Connection

Figure 10 shows the connections required between a wired scoreboard and two statistics
displays. The same signal cable routing applies to hockey scoring modules. Refer to Figure 5
for more information about connecting the signal wiring that runs from the scoreboard to the
controller. Refer also to Drawing A-124688 in Appendix B.

1. Follow steps 1-6 in Section 3.4.
2. Connect a

1

/

4

" phone plug between the J32 – SIGNAL OUT jack on top of the

scoreboard to the J31 – SIGNAL IN jack on top of the right (GUEST) stat panel or
scoring module.

3. Connect another

1

/

4

" phone plug between the Signal Out (J32) jack on top of the right

(GUEST) stat panel or scoring module to the J31 – SIGNAL IN jack on top of the left
(HOME) stat panel or scoring module.


Note:
If any scoring modules are to be mounted below the main scoreboard, ensure the
right (GUEST) scoring module has a signal cable connected to the SIGNAL IN jack and
another cable running from the SIGNAL OUT jack to the SIGNAL IN jack of the left
(HOME) scoring module prior to securing the upper scoreboard cabinet(s).

Figure 10: Statistic Display Installation