19

DM-100 Controller Operation

The Petroleum Price Controller LCD display will default to showing the current display

settings on power up. The following text will be shown on the LCD.

LCD Screen

Action

LINE PRICE
1

$1.23 9/10

<EDIT> TO MODIFY
1

$1.23 9/10

The display will toggle between these two

screens.

Press the up or down arrow keys <

↑↓> to scroll

through the current setting for any of the lines

on the display.

Press the <ENTER/EDIT> key to modify any of

the line settings.

To modify Price Line Settings:

1. Press either the <EDIT> key during operation or the <MENU> key. (Refer to the

following Menu Items chart.)

2. The following keys identify editable items:

L = Current line number to be edited

D.CC = Current dollars and cents value to edit

T = Current tenths of cent value to edit

LCD Screen

Action

EDIT LINE L
$D.CC T/10

Press any of the number keys to edit the price

value for this line. Press the down arrow key <

>

to modify the value of the 1/10-cent data for this

line (read Note following).

Press <ENTER> to accept the new value or

press <CLEAR> to abort the changes.

Note: The flashing asterisk on the LCD shows

the current data being edited.

Many displays do not have a changeable 1/10-

cent digit. Changing the tenths-cent value from 9

on these digits will make the digit appear

incorrect.