6 initial operation information, Initial operation information -8 – Daktronics AE-3010-7.6-R,G,A User Manual

Page 38

Advertising
background image

Maintenance and Troubleshooting

4-8

Cannot communicate to section of
the network of displays

•

Check the cabling between displays.

•

Check for bad input on first bad display.

•

Check for bad output on the last good
display.

•

Switch the suspected bad display with
a known good display.

•

Check displays and software for correct
addressing

Display is stuck on bright or dim.

•

Check Manual/Auto dimming in Venus
1500 software.

•

Check light detector cable.

•

Replace light detector.

•

Replace controller board.

4.6 Initial Operation Information

Each time the display is powered up, the display will run through an initialization in
which it will display the following:

1. Output Test (DDD’s)
2. Product Name (Galaxy)
3. Display Size (Row x Column)
4. Firmware Number (ED10134)
5. Firmware Revision (Rev X.XX)
6. COM1 Configuration (C1: V15/RTD)
7. COM2 Configuration (C2: None)
8. Line Frequency (60 Hz)
9. Hardware Address (HW: XX)
10. Software Address (SW: XX)
11. Display Name
12. If Modem is Present (Modem)

Advertising